Search results


 
  1. J

    Thermocouple Pit Probe Issues on new HM build

    This was bought from the HM store with the TC surface mount stuff pre-soldered. So that wasn't my handy work :) . It says No Probe. So, some discouraging results.... Presuming I am measuring the proper spots, I measured about 1.53V. It seemed really finicky though.. at one point it was 1.0V...
  2. J

    Thermocouple Pit Probe Issues on new HM build

    Tried the thermocouple amp test to the best of my ability. Using a AA battery (not sure this is enough to make the test work), which measured 1.48V, hooked up as instructed. Best measurement was 1.36V with most being down about 1V.
  3. J

    Thermocouple Pit Probe Issues on new HM build

    Shorted the pins, still ~561F. Can I try the thermocouple amp testing even after things have been mounted? Yes I see the warning about the 3V limit, but didn't know if I can still use the same test. Anything obvious on these pics?
  4. J

    Thermocouple Pit Probe Issues on new HM build

    Thanks as usual Bryan, will try tonight.
  5. J

    Thermocouple Pit Probe Issues on new HM build

    First build, HM 4.2.4 w/ thermocouple pit. After installing in a case, I am getting a reading of 561f [plus/minus 3f] on the pit probe. Everything else seems to function fine including the thermistor probes. I just got the Adapt-a-Damper working tonight as well so almost ready to put it in...
  6. J

    HeaterMeter Pit Probe Error

    Bryan, I'll keep an eye on it and will reach out if it reoccurs. Thanks for the quick followup and details.
  7. J

    HeaterMeter Pit Probe Error

    How long is the config expected to persist once set? I had this issue, then updated it to thermocouple and it was fixed. The next day I plugged in the HM again and the config had reverted to thermistor. Sorry if I am thread hijacking; will repost if needed.

 